iFIU – Failure Insertion Unit

iSyst offers the Failure Insertion Unit iFIU for precise injection of diverse errors into embedded systems being tested. The iFIU is controlled via a CAN bus. Signal paths (failure location) support continuous currents of up to 30 A.

Each signal can be individually interrupted or switched to up to two sensor cables, meaning that independent short circuits and cross connections are possible.

This test component is standard in our own HIL systems, but can also provide valuable support in other manufacturers HIL systems.

 